Hey, your browser is out of date!

We've noticed you're currently using an old version of IE.
We really recommend you update your browser.

Our Products

No items found.

Dräger X-am® 5000

Dräger X-am® 5000 belongs to a generation of gas detector
Color
Black/Silver
Size

The Dräger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine.

Buy Now
The Dräger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine. *1 to 5 gas detection device *for personal air monitoring *detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations Despite its advanced functionality, the Dräger X-am 5000's practical mobile phone design and light weight make it comfortable to carry. Reduced to its essentials, the two button control panel and easy to follow menu allow for intuitive use. It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the Dräger X-am 5000's sensors makes more applications possible, including rental equipment. For improved safety when facing unknown and potentially explosive hazards – the Dräger X-am 5000 provides dependable warnings in the event of explosive atmospheres thanks to the high level of sensitivity of the innovative catalytic Ex sensor. It not only responds quickly to explosive gases and combustible organic vapors, but is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination with its long term stability this offers an extraordinary long expected sensor lifetime of more than 4 years. This reduces your operational costs. Equipped with durable XXS sensor technology, the Dräger X-am 5000 offers maximum safety at extremely low operational costs. The sensor's resistance, in combination with its long term stability, provides the sensor with a lifetime in excess of four years, which can help reduce your operational costs.
ATEX I M1 Ex da ia I Ma II 1G Ex da ia IIC T4/T3 Ga IECEx IECExEx da ia I Ma Ex da ia IIC T4/T3 Ga CSA (Canada & USA) Class I Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3 A/Ex da ia IIC T4/T3 /Ga EN 50104 O2 EN 45544-1, EN 45544-2 CO & H2S Measurement performance certificate EN 60079-29-1 Methane to nonane, H2 CE mark Electromagnetic Compatibility (Directive 2014/30/EU) MED Marine Equipment Directive (Directive 2014/90/EU) Approvals EAC PO Ex da ia I Ma X 0Ex da ia IIC T4/T3 Ga X
Specification

The Dräger X-am® 5000 belongs to a generation of gas detectors, developed especially for personal monitoring applications. This 1- to 5-gas detector reliably measures combustible gases and vapors as well as oxygen and harmful concentrations of toxic gases, organic vapors, Odorant and Amine. *1 to 5 gas detection device *for personal air monitoring *detection of flammable and toxic gases and organic vapours as well as oxygen and harmful concentrations Despite its advanced functionality, the Dräger X-am 5000's practical mobile phone design and light weight make it comfortable to carry. Reduced to its essentials, the two button control panel and easy to follow menu allow for intuitive use. It is easy to exchange, upgrade or calibrate the sensors to other gases. The ability to customize the Dräger X-am 5000's sensors makes more applications possible, including rental equipment. For improved safety when facing unknown and potentially explosive hazards – the Dräger X-am 5000 provides dependable warnings in the event of explosive atmospheres thanks to the high level of sensitivity of the innovative catalytic Ex sensor. It not only responds quickly to explosive gases and combustible organic vapors, but is also highly resistant against sensor poisons such as silicone and hydrogen sulfide. In combination with its long term stability this offers an extraordinary long expected sensor lifetime of more than 4 years. This reduces your operational costs. Equipped with durable XXS sensor technology, the Dräger X-am 5000 offers maximum safety at extremely low operational costs. The sensor's resistance, in combination with its long term stability, provides the sensor with a lifetime in excess of four years, which can help reduce your operational costs.

Certification & Standards

ATEX I M1 Ex da ia I Ma II 1G Ex da ia IIC T4/T3 Ga IECEx IECExEx da ia I Ma Ex da ia IIC T4/T3 Ga CSA (Canada & USA) Class I Div. 1 Group A, B, C, D, E, F, G T.-Code T4/T3 A/Ex da ia IIC T4/T3 /Ga EN 50104 O2 EN 45544-1, EN 45544-2 CO & H2S Measurement performance certificate EN 60079-29-1 Methane to nonane, H2 CE mark Electromagnetic Compatibility (Directive 2014/30/EU) MED Marine Equipment Directive (Directive 2014/90/EU) Approvals EAC PO Ex da ia I Ma X 0Ex da ia IIC T4/T3 Ga X

Our Partners

We are the Top Dealers of leading Brands

Contact Us

Let’s talk about
the Business...

Connect with us